Changes

added more PDF links
Line 4: Line 4:     
== Model Numbers ==
 
== Model Numbers ==
 +
 +
In the DZB312 series manual:
    
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF)
 
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF)
 +
 +
In the DZB300 series manual:
 +
 +
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=7 Page 7] (marked 7 in the PDF) shows the model number scheme
 +
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8] (marked 9 in the PDF) shows a table of model numbers and recommended component sizing
 +
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=47 Page 47] (marked 88 in the PDF) shows the specifications based off the model number ranges
    
== Wiring Diagram ==
 
== Wiring Diagram ==
 +
 +
In the DZB312 series manual:
    
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF)
 
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF)
 +
 +
In the DZB300 series manual:
 +
 +
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8-9] (marked 10-11 in the PDF) shows an overview of the wiring
 +
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=9 Page 9] (marked 12 in the PDF) shows a the power terminal pinout
 +
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=10 Page 10] (marked 13 in the PDF) shows a the control terminal pinout
    
== Dimensions ==
 
== Dimensions ==
 +
 +
In the DZB312 series manual:
    
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF)
 
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF)
   −
== Modbus control ==
+
In the DZB300 series manual:
 +
 
 +
* https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=55 Page 55] (marked 104 in the PDF)
 +
 
 +
== Parameters ==
 +
 
 +
In the DZB312 series manual:
 +
 
 +
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=10 Page 10] (marked 18 in the PDF) shows the list of parameters
 +
 
 +
In the DZB300 series manual:
 +
 
 +
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=15 Page 15] (marked 23 in the PDF) shows the list of parameters
 +
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=21 Page 21] (marked 36 in the PDF) shows the detailed description of the parameters
   −
=== VFD parameters ===
+
== Fault Codes ==
    
In the DZB312 series manual:
 
In the DZB312 series manual:
   −
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=10 Page 10] (17 in the PDF) gives the parameter list
+
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=16 Page 16] (marked 29 in the PDF) shows a list of fault codes
 +
 
 +
In the DZB300 series manual:
 +
 
 +
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=43 Page 43] (marked 79 in the PDF) has a flowchart for diagnosing issues
 +
 
 +
== Modbus control ==
   −
Here are the ones relevant for Modbus control:
+
=== VFD parameters ===
 +
 
 +
Parameters relevant for Modbus control:
    
{| class="wikitable"
 
{| class="wikitable"
Line 139: Line 178:  
| 0x2000
 
| 0x2000
 
| 8192
 
| 8192
| R/W ?
+
| R/W
 
| -10000 - +100000 (frequency/PID percentage * 100)
 
| -10000 - +100000 (frequency/PID percentage * 100)
| frequency/PID setpoint percentage (?)
+
| frequency/PID setpoint percentage
 
|-
 
|-
 
| 0x3000
 
| 0x3000
Line 170: Line 209:  
| 12292
 
| 12292
 
| R
 
| R
| ???
+
| (rpm using parameter F1.03)
 
| output speed
 
| output speed
 
|-
 
|-
Line 182: Line 221:  
| 12294
 
| 12294
 
| R
 
| R
|  
+
| ???
 
| output torque
 
| output torque
 
|-
 
|-
Line 218: Line 257:  
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2
 
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2
   −
# set the output frequency/PID percentage (percentage * 100)
+
# set the output frequency/rpm/PID percentage (percentage * 100)
 
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- 10000
 
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- 10000
   Line 238: Line 277:  
# monitor output voltage
 
# monitor output voltage
 
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003
 
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003
 +
 +
# monitor output rpm
 +
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3004
    
# monitor inverter fault
 
# monitor inverter fault
Line 248: Line 290:     
[[Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf]] (not available online?)
 
[[Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf]] (not available online?)
 +
 +
[[Media:Fuling_DZB300_Series_Inverter_User_Manual.pdf]]
    
== Online Resources ==
 
== Online Resources ==