Line 4: |
Line 4: |
| | | |
| == Model Numbers == | | == Model Numbers == |
| + | |
| + | In the DZB312 series manual: |
| | | |
| * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) |
| + | |
| + | In the DZB300 series manual: |
| + | |
| + | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=7 Page 7] (marked 7 in the PDF) shows the model number scheme |
| + | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8] (marked 9 in the PDF) shows a table of model numbers and recommended component sizing |
| + | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=47 Page 47] (marked 88 in the PDF) shows the specifications based off the model number ranges |
| | | |
| == Wiring Diagram == | | == Wiring Diagram == |
| + | |
| + | In the DZB312 series manual: |
| | | |
| * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF) | | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF) |
| + | |
| + | In the DZB300 series manual: |
| + | |
| + | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8-9] (marked 10-11 in the PDF) shows an overview of the wiring |
| + | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=9 Page 9] (marked 12 in the PDF) shows a the power terminal pinout |
| + | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=10 Page 10] (marked 13 in the PDF) shows a the control terminal pinout |
| | | |
| == Dimensions == | | == Dimensions == |
| + | |
| + | In the DZB312 series manual: |
| | | |
| * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) |
| | | |
− | == Modbus control == | + | In the DZB300 series manual: |
| + | |
| + | * https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=55 Page 55] (marked 104 in the PDF) |
| + | |
| + | == Parameters == |
| + | |
| + | In the DZB312 series manual: |
| + | |
| + | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=10 Page 10] (marked 18 in the PDF) shows the list of parameters |
| + | |
| + | In the DZB300 series manual: |
| + | |
| + | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=15 Page 15] (marked 23 in the PDF) shows the list of parameters |
| + | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=21 Page 21] (marked 36 in the PDF) shows the detailed description of the parameters |
| | | |
− | === VFD parameters === | + | == Fault Codes == |
| | | |
| In the DZB312 series manual: | | In the DZB312 series manual: |
| | | |
− | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=10 Page 10] (17 in the PDF) gives the parameter list | + | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=16 Page 16] (marked 29 in the PDF) shows a list of fault codes |
| + | |
| + | In the DZB300 series manual: |
| + | |
| + | * [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=43 Page 43] (marked 79 in the PDF) has a flowchart for diagnosing issues |
| + | |
| + | == Modbus control == |
| | | |
− | Here are the ones relevant for Modbus control:
| + | === VFD parameters === |
| + | |
| + | Parameters relevant for Modbus control: |
| | | |
| {| class="wikitable" | | {| class="wikitable" |
Line 139: |
Line 178: |
| | 0x2000 | | | 0x2000 |
| | 8192 | | | 8192 |
− | | R/W ? | + | | R/W |
| | -10000 - +100000 (frequency/PID percentage * 100) | | | -10000 - +100000 (frequency/PID percentage * 100) |
− | | frequency/PID setpoint percentage (?) | + | | frequency/PID setpoint percentage |
| |- | | |- |
| | 0x3000 | | | 0x3000 |
Line 170: |
Line 209: |
| | 12292 | | | 12292 |
| | R | | | R |
− | | ??? | + | | (rpm using parameter F1.03) |
| | output speed | | | output speed |
| |- | | |- |
Line 182: |
Line 221: |
| | 12294 | | | 12294 |
| | R | | | R |
− | | | + | | ??? |
| | output torque | | | output torque |
| |- | | |- |
Line 218: |
Line 257: |
| ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2 | | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2 |
| | | |
− | # set the output frequency/PID percentage (percentage * 100) | + | # set the output frequency/rpm/PID percentage (percentage * 100) |
| ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- 10000 | | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- 10000 |
| | | |
Line 238: |
Line 277: |
| # monitor output voltage | | # monitor output voltage |
| ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003 | | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003 |
| + | |
| + | # monitor output rpm |
| + | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3004 |
| | | |
| # monitor inverter fault | | # monitor inverter fault |
Line 248: |
Line 290: |
| | | |
| [[Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf]] (not available online?) | | [[Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf]] (not available online?) |
| + | |
| + | [[Media:Fuling_DZB300_Series_Inverter_User_Manual.pdf]] |
| | | |
| == Online Resources == | | == Online Resources == |