Changes

added Modbus related parameters
Line 16: Line 16:     
* [https://www.cncwiki.org/images/1/13/FoLinn_BD600_Series_User_Manual.pdf#page=86 Page 86] (165 in the PDF) shows a table of dimensions
 
* [https://www.cncwiki.org/images/1/13/FoLinn_BD600_Series_User_Manual.pdf#page=86 Page 86] (165 in the PDF) shows a table of dimensions
 +
 +
== Modbus control ==
 +
 +
=== VFD parameters ===
 +
 +
{| class="wikitable"
 +
! No.
 +
! Name
 +
! Values
 +
|-
 +
| F13.00
 +
| Slave Address
 +
| 1-9?
 +
|-
 +
| F13.01
 +
| Baudrate
 +
| 0: 300<br/>1: 600<br/>2: 1,200<br/>3: 2,400<br/>4: 4,800<br/>5: 9,600<br/>6: 19,200<br/>7: 38,400<br/>8: 57,600<br/>9: 115,200
 +
|-
 +
| F13.02
 +
| Data Format
 +
| 0: 8 data bits, no parity, 2 stop bits<br/>1: 8 data bits, even parity, 1 stop bit<br/>2: 8 data bits, odd parity, 1 stop bit<br/>3: 8 data bits, no parity, 1 stop bit
 +
|-
 +
| F13.03
 +
| Response Delay
 +
| 0-20ms
 +
|-
 +
| F13.04
 +
| Communication Timeout
 +
| 0.0-60.0s
 +
|-
 +
| F13.05
 +
| Modbus Protocol
 +
| 0: proprietary</br>1: standard
 +
|-
 +
| F13.06
 +
| Current Fixed Point Resolution
 +
| 0: 0.01A<br/>1: 0.1A
 +
|}
    
== PDFs ==
 
== PDFs ==