AutomationDirect GS2 Series VFDs

From CNC Wiki
Jump to navigation Jump to search

Overview

Chinese variable frequency drives (VFDs). They feature Modbus/RS-485 support.

Model Numbers

  • Page 11 (1-3 in the PDF) shows the model number scheme

Wiring Diagram

  • Page 24 (2-8 in the PDF) shows the power input/output terminal layout
  • Page 26 (2-10 in the PDF) shows the control terminal layout
  • Page 27 (2-11 in the PDF) shows an overview of the wiring
  • Page 134 (5-30 in the PDF) shows the RS-232/RS-485 wiring

NOTE: the manual lists the RS-485 wiring SG+ and SG- swapped! SG+ is really B- and SG- is really A+, this is the correct RJ12 (6P4C) pinout:

RJ12 Pin Function
2 GND
3 A+ (manual says SG-!)
4 B- (manual says SG+!)
5 +5V

Dimensions

Software

  • Page 168 (A-22 in the PDF) mentions the GSoft software

Software & Firmware Downloads

Filename Size MD5 SHA1 SHA256
gsoftInstall_v4_0_7_db7_0_9.zip 22,525,331 bytes 829949476babd049043abc22f35bf305 e59f849056f589aff632d6f6208c7e7b4f37bcc0 9daf832d4a91dcaed3a684fd9a0c3c442d9d8c1a58ef322db8072594427b9835

Parameters

  • Page 44 (4-2 in the PDF) lists the parameters
  • Page 53 (4-11 in the PDF) gives detailed parameter descriptions

Alarm Codes

  • Page 143 (6-3 in the PDF) lists the LCD fault codes

Modbus Control

VFD parameters

Modbus Address Parameter No. Default Value Required Value Description
0x0300 P03.00 00: Operation determined by digital keypad 04: Operation determined by RS-485 interface, keypad STOP is disabled Source of Operation Command
0x0400 P04.00 00: Frequency determined by keypad potentiometer 05: Frequency determined by RS-232C/RS-485 communication interface Source of Frequency Command
0x0900 P09.00 1 1 Slave Address
0x0901 P09.01 01: 9,600 baud 01: 9,600 baud Baudrate
0x0902 P09.02 00: MODBUS ASCII, 7N2 04: MODBUS RTU, 8E1 Communication Protocol
0x0903 P09.03 00: display fault and continue 02: display fault and coast to stop Transmission Fault Treatment
0x0904 P09.04 00: disable 01: enable Time Out Detection
0x0905 P09.05 0.5 seconds 2.0 seconds Time Out Duration

Modbus registers

  • Page 108 (5-4 in the PDF) lists the parameter registers
  • Page 113 (5-9 in the PDF) lists the status registers

Command registers:

Parameter No. Register No. (hex) Register No. (decimal) Values Description
P09.26 0x091A 2330 0 - 4000 (Hz * 10) Serial Comm Speed Reference
P09.27 0x091B 2331 00: Stop
01: Run
Serial Comm RUN Command
P09.28 0x091C 2332 00: Forward
01: Reverse
Serial Comm Direction Command
P09.29 0x091D 2333 00: No fault
01: External fault
Serial Comm External Fault
P09.30 0x091E 2334 00: No action
01: Fault reset
Serial Comm Fault Reset
P09.31 0x091F 2335 00: Stop
01: Jog
Serial Comm JOG Command

Status registers:

Register No. (hex) Register No. (decimal) Description
0x2100 8448 Status Monitor 1
0x2101 8449 Status Monitor 2
0x2102 8450 Frequency Command F
0x2103 8451 Output Frequency H
0x2104 8452 Output Current A
0x2105 8453 DC Bus Voltage d
0x2106 8454 Output Voltage U
0x2107 8455 Motor RPM
0x2108 8456 Scale Frequency (Low Word)
0x2109 8457 Scale Frequency (High Word)
0x210A 8458 Power Factor Angle
0x210B 8459 % Load
0x2110 8464 Firmware Version

Online Resources

https://cdn.automationdirect.com/static/manuals/gs2m/gs2m.pdf

https://cdn.automationdirect.com/static/specs/oldspec/gs2drive_01_27_22.pdf