Folinn H1 Series VFDs: Difference between revisions
added RS-485 RJ45 pinout table |
added parameters to enable MODBUS timeout fault |
||
| Line 307: | Line 307: | ||
| 2: communication (?) | | 2: communication (?) | ||
| Pause command source | | Pause command source | ||
|} | |||
To configure MODBUS timeout: | |||
{| class="wikitable" | |||
! Parameter No. | |||
! Default Value | |||
! Required Value | |||
! Description | |||
|- | |||
| P01.30 | |||
| 0000 | |||
| 1340: Comparator 1 Output | |||
| Virtual terminal setting | |||
|- | |||
| P03.08 | |||
| 00: no effect | |||
| 17: use P01.30 bit 0 (in single command mode) | |||
| Fault command source | |||
|- | |||
| P12.00 | |||
| 0.0 | |||
| 2.0 (seconds until timeout) | |||
| Free parameter 1 | |||
|- | |||
| P16.00 | |||
| 0000: invalid? | |||
| 1044: use P10.44 "communication timeout" | |||
| Comparator 1 input parameter selection | |||
|} | |} | ||