SUNFAR E380 Series VFDs: Difference between revisions

fixed broken link
added Modbus information
Line 48: Line 48:
* [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=76 Page 76] (69 in the PDF) descrives the proprietary SUNFAR protocol
* [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=76 Page 76] (69 in the PDF) descrives the proprietary SUNFAR protocol
* [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=93 Page 93] (86 in the PDF) describes the Modbus protocol
* [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=93 Page 93] (86 in the PDF) describes the Modbus protocol
=== VFD Parameters ===
{| class="wikitable"
! Parameter No.
! Default Value
! Required Value
! Description
|-
| F0.1
| 0: keypad (not POT)
| 2: RS-485
| Frequency Source
|-
| F0.4
| 1: external terminals
| 2: RS-485
| Run Source
|-
| F9.0
| 0014: proprietary protocol, 9600 baud, even parity
| 0114: MODBUS RTU protocol, 9600 baud, even parity
| RS-485 Mode
|-
| F9.1
| 0?
| 1
| Slave Address
|-
| F9.2
| 5ms
| 5ms
| Response Delay Time
|-
| F9.3
| 0010: keep running
| 0000: stop running
| Timeout & Master/Slave Behavior
|-
| F9.4
| 2.0 s
| 10.0 s
| Communication Timeout
|}
=== Modbus Registers ===
Readable registers (function code 3):
{| class="wikitable"
! Address
! Value
! Description
|-
| 0x2000
| 0x0000: Slave DC voltage is not prepared<br/>0x0001: Slave forward running<br/>0x0002: Slave reverse running<br/>0x0003: Slave stop<br/>0x0004: Slave forward jog running<br/>0x0005: Slave reverse jog running<br/>0x0011: Forward accelerating<br/>0x0012: Reverse accelerating<br/>0x0013: Instantaneous stop and restart<br/>0x0014: Forward decelerating<br/>0x0015: Reverse decelerating<br/>0x0016: Slave is under DC braking status<br/>0x0020: Slave is on fault status
| Inverter Status
|-
| 0x2001
| ?
| Fault Information
|}
Writable registers (function 6):
{| class="wikitable"
! Address
! Value
! Description
|-
| 0x1000
| ?
| "Given by PID"?
|-
| 0x1001
| 0x00: Invalid<br/>0x01: Forward run to start<br/>0x02: Reversion run to start<br/>0x03: Stop<br/>0x04: Slave forward jog<br/>0x05: Slave reversion jog<br/>0x06: Jog run to stop<br/>0x20: Slave fault reset<br/>
| Operating Command
|-
| 0x1002
| 0.00 - 600.00 Hz
| Frequency Setting
|}


== Online Resources ==
== Online Resources ==