DEALOUR 13ic/83ic Series Servo Drives: Difference between revisions

added connector information
added parameter, alarm codes, and Modbus information
Line 22: Line 22:


* [https://www.cncwiki.org/images/5/58/DEALOUR_DO-13ic_and_DO-83ic_Absolute_Value_Series_Servo_Drive_Manual_V022400_English.pdf#page=9 Page 9] (1 in the PDF) shows the dimensions
* [https://www.cncwiki.org/images/5/58/DEALOUR_DO-13ic_and_DO-83ic_Absolute_Value_Series_Servo_Drive_Manual_V022400_English.pdf#page=9 Page 9] (1 in the PDF) shows the dimensions
== Parameters ==
* [https://www.cncwiki.org/images/5/58/DEALOUR_DO-13ic_and_DO-83ic_Absolute_Value_Series_Servo_Drive_Manual_V022400_English.pdf#page=53 Page 53] (45 in the PDF) shows the list of "PA mode" parameters
* [https://www.cncwiki.org/images/5/58/DEALOUR_DO-13ic_and_DO-83ic_Absolute_Value_Series_Servo_Drive_Manual_V022400_English.pdf#page=58 Page 58] (50 in the PDF) shows the "detailed explanation" of the parameters
== Alarm Codes ==
* [https://www.cncwiki.org/images/5/58/DEALOUR_DO-13ic_and_DO-83ic_Absolute_Value_Series_Servo_Drive_Manual_V022400_English.pdf#page=73 Page 73] (65 in the PDF) shows the list of alarm codes
* [https://www.cncwiki.org/images/5/58/DEALOUR_DO-13ic_and_DO-83ic_Absolute_Value_Series_Servo_Drive_Manual_V022400_English.pdf#page=74 Page 74] (66 in the PDF) has an alarm code troubleshooting guide
== Modbus Control ==
Parameters related to Modbus/RS-485:
{| class="wikitable"
! Name
! Values
! Default
! Description
|-
| PA80
| 1-32,767 (??? shouldn't it be 1-247?)
| 1
| Modbus Slave Address
|-
| PA81
| <del>0: 4,800 baud</del> (documented, but not available)<br/>1: 9,600 baud<br/>2: 19,200 baud<br/>3: 38,400 baud<br/>4: ??? (undocumented)<br/>5: ??? (undocumented)
| 2: 19,200 baud
| Modbus Baud Rate
|-
| PA82
| 0: odd<br/>1: even
| 0: odd
| Modbus Parity Type
|}
In all cases, the fame format is Modbus RTU (binary) with 1 start bit, 8 data bits, PA82 selected parity, and 1 stop bit.


== Replacement Parts ==