Folinn BD600 Series VFDs: Difference between revisions

initial page creation
 
added Modbus related parameters
Line 16: Line 16:


* [https://www.cncwiki.org/images/1/13/FoLinn_BD600_Series_User_Manual.pdf#page=86 Page 86] (165 in the PDF) shows a table of dimensions
* [https://www.cncwiki.org/images/1/13/FoLinn_BD600_Series_User_Manual.pdf#page=86 Page 86] (165 in the PDF) shows a table of dimensions
== Modbus control ==
=== VFD parameters ===
{| class="wikitable"
! No.
! Name
! Values
|-
| F13.00
| Slave Address
| 1-9?
|-
| F13.01
| Baudrate
| 0: 300<br/>1: 600<br/>2: 1,200<br/>3: 2,400<br/>4: 4,800<br/>5: 9,600<br/>6: 19,200<br/>7: 38,400<br/>8: 57,600<br/>9: 115,200
|-
| F13.02
| Data Format
| 0: 8 data bits, no parity, 2 stop bits<br/>1: 8 data bits, even parity, 1 stop bit<br/>2: 8 data bits, odd parity, 1 stop bit<br/>3: 8 data bits, no parity, 1 stop bit
|-
| F13.03
| Response Delay
| 0-20ms
|-
| F13.04
| Communication Timeout
| 0.0-60.0s
|-
| F13.05
| Modbus Protocol
| 0: proprietary</br>1: standard
|-
| F13.06
| Current Fixed Point Resolution
| 0: 0.01A<br/>1: 0.1A
|}


== PDFs ==
== PDFs ==