SUNFAR E380 Series VFDs: Difference between revisions

added Modbus information
added more MODBUS register information
Line 98: Line 98:


{| class="wikitable"
{| class="wikitable"
! Parameter No.
! Address
! Address
! Value
! Value
! Description
! Description
|-
|-
|
| 0x2000
| 0x2000
| 0x0000: Slave DC voltage is not prepared<br/>0x0001: Slave forward running<br/>0x0002: Slave reverse running<br/>0x0003: Slave stop<br/>0x0004: Slave forward jog running<br/>0x0005: Slave reverse jog running<br/>0x0011: Forward accelerating<br/>0x0012: Reverse accelerating<br/>0x0013: Instantaneous stop and restart<br/>0x0014: Forward decelerating<br/>0x0015: Reverse decelerating<br/>0x0016: Slave is under DC braking status<br/>0x0020: Slave is on fault status
| 0x0000: Slave DC voltage is not prepared<br/>0x0001: Slave forward running<br/>0x0002: Slave reverse running<br/>0x0003: Slave stop<br/>0x0004: Slave forward jog running<br/>0x0005: Slave reverse jog running<br/>0x0011: Forward accelerating<br/>0x0012: Reverse accelerating<br/>0x0013: Instantaneous stop and restart<br/>0x0014: Forward decelerating<br/>0x0015: Reverse decelerating<br/>0x0016: Slave is under DC braking status<br/>0x0020: Slave is on fault status
| Inverter Status
| Inverter Status
|-
|-
|
| 0x2001
| 0x2001
| ?
| ?
| Fault Information
| Fault Information
|-
| d-00 - d-37
| 0xD000 - 0xD025
|
| Monitoring
|-
| F0.0 - F0.18?
| 0xF000 - 0xF0D1
|
| F0.xx
|-
| F1.0 - F1.18?
| 0xF100 - 0xF1BE
|
| F1.xx
|-
| F2.0 - F2.18?
| 0xF200 - 0xF2AB
|
| F2.xx
|-
| F3.0 - F3.16?
| 0xF300 - 0xF398
|
| F3.xx
|-
| F4.0 - F4.28?
| 0xF400 - 0xF487
|
| F4.xx
|-
| F5.0 - F5.26?
| 0xF500 - 0xF56A
|
| F5.xx
|-
| F6.0 - F6.19?
| 0xF600 - 0xF64F
|
| F6.xx
|-
| F7.0 - F7.8?
| 0xF700 - 0xF739
|
| F7.xx
|-
| F8.0 - F8.24?
| 0xF800 - 0xF832
|
| F8.xx
|-
| F9.0 - F9.11?
| 0xF900 - 0xF919
|
| F9.xx
|-
| rowspan="2" | FC.0 - FC.13?
| 0xFA00 - 0xFA0D
|
| FC.xx?
|-
| 0xFC00 - 0xFC0D
|
| FC.xx?
|}
|}