SUNFAR E380 Series VFDs: Difference between revisions

From CNC Wiki
Jump to navigation Jump to search
updated E550 manual link
added Chinese company name and website links
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
== Overview ==
== Overview ==


Variable Frequency Drives (VFDs) made by SHENZHEN SUNFAR ELECTRIC TECHNOLOGIES CO.,LTD.
Variable Frequency Drives (VFDs) made by "深圳市四方电气技术有限公司" (Shenzhen Sunfar Electric Technology Co., Ltd.), now known as "深圳市四方电气技术有限公司" (Shenzhen Simphoenix Electric Technology Co., Ltd).


== Model Numbers ==
== Model Numbers ==
Line 48: Line 48:
* [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=76 Page 76] (69 in the PDF) descrives the proprietary SUNFAR protocol
* [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=76 Page 76] (69 in the PDF) descrives the proprietary SUNFAR protocol
* [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=93 Page 93] (86 in the PDF) describes the Modbus protocol
* [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=93 Page 93] (86 in the PDF) describes the Modbus protocol
=== VFD Parameters ===
{| class="wikitable"
! Parameter No.
! Default Value
! Required Value
! Description
|-
| F0.1
| 0: keypad (not POT)
| 2: RS-485
| Frequency Source
|-
| F0.4
| 1: external terminals
| 2: RS-485
| Run Source
|-
| F9.0
| 0014: proprietary protocol, 9600 baud, even parity
| 0114: MODBUS RTU protocol, 9600 baud, even parity
| RS-485 Mode
|-
| F9.1
| 0?
| 1
| Slave Address
|-
| F9.2
| 5ms
| 5ms
| Response Delay Time
|-
| F9.3
| 0010: keep running
| 0000: stop running
| Timeout & Master/Slave Behavior
|-
| F9.4
| 2.0 s
| 10.0 s
| Communication Timeout
|}
=== Modbus Registers ===
Readable registers (function code 3):
{| class="wikitable"
! Parameter No.
! Address
! Value
! Description
|-
|
| 0x2000
| 0x0000: Slave DC voltage is not prepared<br/>0x0001: Slave forward running<br/>0x0002: Slave reverse running<br/>0x0003: Slave stop<br/>0x0004: Slave forward jog running<br/>0x0005: Slave reverse jog running<br/>0x0011: Forward accelerating<br/>0x0012: Reverse accelerating<br/>0x0013: Instantaneous stop and restart<br/>0x0014: Forward decelerating<br/>0x0015: Reverse decelerating<br/>0x0016: Slave is under DC braking status<br/>0x0020: Slave is on fault status
| Inverter Status
|-
|
| 0x2001
| ?
| Fault Information
|-
| d-00 - d-37
| 0xD000 - 0xD025
|
| Monitoring
|-
| F0.0 - F0.18?
| 0xF000 - 0xF0D1
|
| F0.xx
|-
| F1.0 - F1.18?
| 0xF100 - 0xF1BE
|
| F1.xx
|-
| F2.0 - F2.18?
| 0xF200 - 0xF2AB
|
| F2.xx
|-
| F3.0 - F3.16?
| 0xF300 - 0xF398
|
| F3.xx
|-
| F4.0 - F4.28?
| 0xF400 - 0xF487
|
| F4.xx
|-
| F5.0 - F5.26?
| 0xF500 - 0xF56A
|
| F5.xx
|-
| F6.0 - F6.19?
| 0xF600 - 0xF64F
|
| F6.xx
|-
| F7.0 - F7.8?
| 0xF700 - 0xF739
|
| F7.xx
|-
| F8.0 - F8.24?
| 0xF800 - 0xF832
|
| F8.xx
|-
| F9.0 - F9.11?
| 0xF900 - 0xF919
|
| F9.xx
|-
| rowspan="2" | FC.0 - FC.13?
| 0xFA00 - 0xFA0D
|
| FC.xx?
|-
| 0xFC00 - 0xFC0D
|
| FC.xx?
|}
Writable registers (function 6):
{| class="wikitable"
! Address
! Value
! Description
|-
| 0x1000
| ?
| "Given by PID"?
|-
| 0x1001
| 0x00: Invalid<br/>0x01: Forward run to start<br/>0x02: Reversion run to start<br/>0x03: Stop<br/>0x04: Slave forward jog<br/>0x05: Slave reversion jog<br/>0x06: Jog run to stop<br/>0x20: Slave fault reset<br/>
| Operating Command
|-
| 0x1002
| 0.00 - 600.00 Hz
| Frequency Setting
|}


== Online Resources ==
== Online Resources ==
[https://www.simphoenix.com.cn/product/Detail.aspx?id=100000023014378 VS500雕刻机专用变频器] (VFD product page from the same company)
[https://www.simphoenix.com.cn/support/index.aspx?nc=101033004 深圳市四方电气技术有限公司] (product support page listing the E380 model)
[https://www.simphoenix.com.cn/UploadFiles/Files/2023/11/20231107052736781.pdf SUNFAR E380 Series Universal Inverter User Manual (V2.7, May 2013, Chinese)]
[https://www.simphoenix.com.cn/UploadFiles/Files/2023/11/20231107054055421.pdf Simphoenix E380 Series Universal Inverter Brochure (Chinese)]


[https://salecnc.com/manuals/Inverter/E380%20Series%20Manual.pdf SUNFAR E380 Series of General Purpose Inverter Operation Manual] (salecnc.com, 88 pages)
[https://salecnc.com/manuals/Inverter/E380%20Series%20Manual.pdf SUNFAR E380 Series of General Purpose Inverter Operation Manual] (salecnc.com, 88 pages)
Line 56: Line 213:


<del>[https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf SUNFAR E550 Series Universal Low-Power Inverter User Manual] (purelogic.ru, 100 pages)</del>
<del>[https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf SUNFAR E550 Series Universal Low-Power Inverter User Manual] (purelogic.ru, 100 pages)</del>
[https://web.archive.org/web/20210829121720/https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf SUNFAR E550 Series Universal Low-Power Inverter User Manual] (purelogic.ru, 100 pages) (Wayback Machine)


[https://cdn.awsli.com.br/298/298780/arquivos/Serie%20e550.pdf SUNFAR E550 Series Universal Low-Power Inverter User Manual]
[https://cdn.awsli.com.br/298/298780/arquivos/Serie%20e550.pdf SUNFAR E550 Series Universal Low-Power Inverter User Manual]

Latest revision as of 09:30, 14 February 2025

Overview

Variable Frequency Drives (VFDs) made by "深圳市四方电气技术有限公司" (Shenzhen Sunfar Electric Technology Co., Ltd.), now known as "深圳市四方电气技术有限公司" (Shenzhen Simphoenix Electric Technology Co., Ltd).

Model Numbers

  • Page 5 shows the layout of the nameplate
  • Page 7 shows the breakdown of the model number
  • Page 9 shows a table of the model specifications

Wiring Diagram

  • Page 17 gives an overview of the power wiring
  • Page 19 gives an more complete overview of the wiring
  • Page 20 shows the power barrier block terminal pinout
  • Page 21 shows the control screw terminal block pinout

Dimensions

  • Page 12 gives the recommended clearances around the VFD in the electrical cabinet
  • Page 14 gives the inverter dimensions based on model type
  • Page 16 gives a table of the dimension values

Parameters

  • Page 29 has the table of parameters
  • Page 39 has the parameter descriptions

Alarm Codes

  • Page 71 has the table of fault codes

Modbus/RS-485 Control

The VFD can be configured to either use Modbus or their proprietary SUNFAR protocol over the RS-485 terminals.

In the salecnc.com manual:

  • Page 78 describes the proprietary SUNFAR RS-485 protocol

In the simphoenix.com manual:

  • Page 96 (92 in the PDF) describes the proprietary SUNFAR RS-485 protocol
  • Page 104 (100 in the PDF) describes the Modbus protocol

In the purelogic.ru manual:

  • Page 76 (69 in the PDF) descrives the proprietary SUNFAR protocol
  • Page 93 (86 in the PDF) describes the Modbus protocol

VFD Parameters

Parameter No. Default Value Required Value Description
F0.1 0: keypad (not POT) 2: RS-485 Frequency Source
F0.4 1: external terminals 2: RS-485 Run Source
F9.0 0014: proprietary protocol, 9600 baud, even parity 0114: MODBUS RTU protocol, 9600 baud, even parity RS-485 Mode
F9.1 0? 1 Slave Address
F9.2 5ms 5ms Response Delay Time
F9.3 0010: keep running 0000: stop running Timeout & Master/Slave Behavior
F9.4 2.0 s 10.0 s Communication Timeout

Modbus Registers

Readable registers (function code 3):

Parameter No. Address Value Description
0x2000 0x0000: Slave DC voltage is not prepared
0x0001: Slave forward running
0x0002: Slave reverse running
0x0003: Slave stop
0x0004: Slave forward jog running
0x0005: Slave reverse jog running
0x0011: Forward accelerating
0x0012: Reverse accelerating
0x0013: Instantaneous stop and restart
0x0014: Forward decelerating
0x0015: Reverse decelerating
0x0016: Slave is under DC braking status
0x0020: Slave is on fault status
Inverter Status
0x2001 ? Fault Information
d-00 - d-37 0xD000 - 0xD025 Monitoring
F0.0 - F0.18? 0xF000 - 0xF0D1 F0.xx
F1.0 - F1.18? 0xF100 - 0xF1BE F1.xx
F2.0 - F2.18? 0xF200 - 0xF2AB F2.xx
F3.0 - F3.16? 0xF300 - 0xF398 F3.xx
F4.0 - F4.28? 0xF400 - 0xF487 F4.xx
F5.0 - F5.26? 0xF500 - 0xF56A F5.xx
F6.0 - F6.19? 0xF600 - 0xF64F F6.xx
F7.0 - F7.8? 0xF700 - 0xF739 F7.xx
F8.0 - F8.24? 0xF800 - 0xF832 F8.xx
F9.0 - F9.11? 0xF900 - 0xF919 F9.xx
FC.0 - FC.13? 0xFA00 - 0xFA0D FC.xx?
0xFC00 - 0xFC0D FC.xx?

Writable registers (function 6):

Address Value Description
0x1000 ? "Given by PID"?
0x1001 0x00: Invalid
0x01: Forward run to start
0x02: Reversion run to start
0x03: Stop
0x04: Slave forward jog
0x05: Slave reversion jog
0x06: Jog run to stop
0x20: Slave fault reset
Operating Command
0x1002 0.00 - 600.00 Hz Frequency Setting

Online Resources

VS500雕刻机专用变频器 (VFD product page from the same company)

深圳市四方电气技术有限公司 (product support page listing the E380 model)

SUNFAR E380 Series Universal Inverter User Manual (V2.7, May 2013, Chinese)

Simphoenix E380 Series Universal Inverter Brochure (Chinese)

SUNFAR E380 Series of General Purpose Inverter Operation Manual (salecnc.com, 88 pages)

SUNFAR E380 Series of General Purpose Inverter Operation Manual (simphoenix.com, 112 pages)

SUNFAR E550 Series Universal Low-Power Inverter User Manual (purelogic.ru, 100 pages)

SUNFAR E550 Series Universal Low-Power Inverter User Manual (purelogic.ru, 100 pages) (Wayback Machine)

SUNFAR E550 Series Universal Low-Power Inverter User Manual

SUNFAR E300 Series Mini-type Integrated Universal Inverter Manual

SUNFAR Product Catalogue

https://web.archive.org/web/20150702063337if_/http://www.simphoenix.com/products_x.aspx?TypeId=8&Id=5

https://web.archive.org/web/20130824110110if_/http://www.sunfardrive.com/products_x.aspx?TypeId=8&Id=5

https://web.archive.org/web/20180111131626/https://www.simphoenix.com/Private/ProductImg/Other/635060392858056687738359022.jpg