In the DZB312 series manual: | |||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | ||
In the DZB300 series manual: | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=7 Page 7] (marked 7 in the PDF) shows the model number scheme | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8] (marked 9 in the PDF) shows a table of model numbers and recommended component sizing | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=47 Page 47] (marked 88 in the PDF) shows the specifications based off the model number ranges | |||
== Wiring Diagram == | == Wiring Diagram == | ||
In the DZB312 series manual: | |||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF) | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF) | ||
In the DZB300 series manual: | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8-9] (marked 10-11 in the PDF) shows an overview of the wiring | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=9 Page 9] (marked 12 in the PDF) shows a the power terminal pinout | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=10 Page 10] (marked 13 in the PDF) shows a the control terminal pinout | |||
== Dimensions == | == Dimensions == | ||
In the DZB312 series manual: | |||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | ||
== | In the DZB300 series manual: | ||
* https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=55 Page 55] (marked 104 in the PDF) | |||
== Parameters == | |||
In the DZB312 series manual: | |||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=10 Page 10] (marked 18 in the PDF) shows the list of parameters | |||
In the DZB300 series manual: | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=15 Page 15] (marked 23 in the PDF) shows the list of parameters | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=21 Page 21] (marked 36 in the PDF) shows the detailed description of the parameters | |||
== | == Fault Codes == | ||
In the DZB312 series manual: | In the DZB312 series manual: | ||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page= | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=16 Page 16] (marked 29 in the PDF) shows a list of fault codes | ||
In the DZB300 series manual: | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=43 Page 43] (marked 79 in the PDF) has a flowchart for diagnosing issues | |||
== Modbus control == | |||
=== VFD parameters === | |||
Parameters relevant for Modbus control: | |||
{| class="wikitable" | {| class="wikitable" | ||
| Line 139: | Line 178: | ||
| 0x2000 | | 0x2000 | ||
| 8192 | | 8192 | ||
| R/W | | R/W | ||
| -10000 - +100000 (frequency/PID percentage * 100) | | -10000 - +100000 (frequency/PID percentage * 100) | ||
| frequency/PID setpoint percentage | | frequency/PID setpoint percentage | ||
|- | |- | ||
| 0x3000 | | 0x3000 | ||
| Line 170: | Line 209: | ||
| 12292 | | 12292 | ||
| R | | R | ||
| | | (rpm using parameter F1.03) | ||
| output speed | | output speed | ||
|- | |- | ||
| Line 182: | Line 221: | ||
| 12294 | | 12294 | ||
| R | | R | ||
| | | ??? | ||
| output torque | | output torque | ||
|- | |- | ||
| Line 218: | Line 257: | ||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2 | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2 | ||
# set the output frequency | # set the output frequency/rpm/PID percentage (percentage * 100) | ||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- 10000 | ||
# monitor command (whatever was previously written, can be invalid) | # monitor command (whatever was previously written, can be invalid) | ||
| Line 238: | Line 277: | ||
# monitor output voltage | # monitor output voltage | ||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003 | ./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003 | ||
# monitor output rpm | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3004 | |||