Fuling DZB312 Series VFDs: Difference between revisions
added more Modbus information |
added more PDF links |
||
| (5 intermediate revisions by the same user not shown) | |||
| Line 4: | Line 4: | ||
== Model Numbers == | == Model Numbers == | ||
In the DZB312 series manual: | |||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | ||
In the DZB300 series manual: | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=7 Page 7] (marked 7 in the PDF) shows the model number scheme | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8] (marked 9 in the PDF) shows a table of model numbers and recommended component sizing | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=47 Page 47] (marked 88 in the PDF) shows the specifications based off the model number ranges | |||
== Wiring Diagram == | == Wiring Diagram == | ||
In the DZB312 series manual: | |||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF) | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF) | ||
In the DZB300 series manual: | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8-9] (marked 10-11 in the PDF) shows an overview of the wiring | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=9 Page 9] (marked 12 in the PDF) shows a the power terminal pinout | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=10 Page 10] (marked 13 in the PDF) shows a the control terminal pinout | |||
== Dimensions == | == Dimensions == | ||
In the DZB312 series manual: | |||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF) | ||
== | In the DZB300 series manual: | ||
* https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=55 Page 55] (marked 104 in the PDF) | |||
== Parameters == | |||
In the DZB312 series manual: | |||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=10 Page 10] (marked 18 in the PDF) shows the list of parameters | |||
In the DZB300 series manual: | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=15 Page 15] (marked 23 in the PDF) shows the list of parameters | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=21 Page 21] (marked 36 in the PDF) shows the detailed description of the parameters | |||
== | == Fault Codes == | ||
In the DZB312 series manual: | In the DZB312 series manual: | ||
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page= | * [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=16 Page 16] (marked 29 in the PDF) shows a list of fault codes | ||
In the DZB300 series manual: | |||
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=43 Page 43] (marked 79 in the PDF) has a flowchart for diagnosing issues | |||
== Modbus control == | |||
=== VFD parameters === | |||
Parameters relevant for Modbus control: | |||
{| class="wikitable" | {| class="wikitable" | ||
| Line 117: | Line 156: | ||
* [http://www.chinafolinn.com/uploads/image/20200602/5ed6233f8b4eb.pdf#page=49 Page 49] (91 in the PDF) describes the Modbus protocol (should be standards compliant) | * [http://www.chinafolinn.com/uploads/image/20200602/5ed6233f8b4eb.pdf#page=49 Page 49] (91 in the PDF) describes the Modbus protocol (should be standards compliant) | ||
* [http://www.chinafolinn.com/uploads/image/20200602/5ed6233f8b4eb.pdf#page=53 Page 53] (100 in the PDF) has the register address map | * [http://www.chinafolinn.com/uploads/image/20200602/5ed6233f8b4eb.pdf#page=53 Page 53] (100 in the PDF) has the register address map | ||
{| class="wikitable" | |||
! Register No. (hex) | |||
! Register No. (dec) | |||
! R/W | |||
! Value | |||
! Description | |||
|- | |||
| 0x1000 | |||
| 4096 | |||
| R/W | |||
| 1-8 (look in manual) | |||
| Modbus controlled command | |||
|- | |||
| 0x1001 | |||
| 4097 | |||
| R | |||
| 1-4 | |||
| inverter state | |||
|- | |||
| 0x2000 | |||
| 8192 | |||
| R/W | |||
| -10000 - +100000 (frequency/PID percentage * 100) | |||
| frequency/PID setpoint percentage | |||
|- | |||
| 0x3000 | |||
| 12288 | |||
| R | |||
| (decimal Hz * 10) | |||
| frequency setpoint | |||
|- | |||
| 0x3001 | |||
| 12289 | |||
| R | |||
| (decimal Hz * 10) | |||
| output frequency | |||
|- | |||
| 0x3002 | |||
| 12290 | |||
| R | |||
| ??? | |||
| output current | |||
|- | |||
| 0x3003 | |||
| 12291 | |||
| R | |||
| (decimal V) | |||
| output voltage | |||
|- | |||
| 0x3004 | |||
| 12292 | |||
| R | |||
| (rpm using parameter F1.03) | |||
| output speed | |||
|- | |||
| 0x3005 | |||
| 12293 | |||
| R | |||
| ??? | |||
| output power | |||
|- | |||
| 0x3006 | |||
| 12294 | |||
| R | |||
| ??? | |||
| output torque | |||
|- | |||
| 0x3007 | |||
| 12295 | |||
| R | |||
| (decimal V * 10) | |||
| DC bus voltage | |||
|- | |||
| 0x5000 | |||
| 20480 | |||
| R | |||
| ??? | |||
| inverter fault address | |||
|- | |||
| 0x5001 | |||
| 20481 | |||
| R | |||
| 0-8 (look in manual) | |||
| Modbus communication fault | |||
|} | |||
=== mbpoll === | |||
<pre># fault reset (need to test) | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 7 | |||
# stop | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 5 | |||
# set forward run | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 1 | |||
# set reverse run | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2 | |||
# set the output frequency/rpm/PID percentage (percentage * 100) | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- 10000 | |||
# monitor command (whatever was previously written, can be invalid) | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 | |||
# monitor inverter status | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1001 | |||
# monitor commanded frequency | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3000 | |||
# monitor output frequency | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3001 | |||
# monitor output current | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3002 | |||
# monitor output voltage | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003 | |||
# monitor output rpm | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3004 | |||
# monitor inverter fault | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x5000 | |||
# monitor Modbus communication fault | |||
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x5001</pre> | |||
== PDFs == | == PDFs == | ||
[[Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf]] (not available online?) | [[Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf]] (not available online?) | ||
[[Media:Fuling_DZB300_Series_Inverter_User_Manual.pdf]] | |||
== Online Resources == | == Online Resources == | ||