added Modbus register tables
added corrected RS-485 pinout
 
Line 12: Line 12:
* [https://cdn.automationdirect.com/static/manuals/gs2m/gs2m.pdf#page=26 Page 26] (2-10 in the PDF) shows the control terminal layout
* [https://cdn.automationdirect.com/static/manuals/gs2m/gs2m.pdf#page=26 Page 26] (2-10 in the PDF) shows the control terminal layout
* [https://cdn.automationdirect.com/static/manuals/gs2m/gs2m.pdf#page=27 Page 27] (2-11 in the PDF) shows an overview of the wiring
* [https://cdn.automationdirect.com/static/manuals/gs2m/gs2m.pdf#page=27 Page 27] (2-11 in the PDF) shows an overview of the wiring
* [https://cdn.automationdirect.com/static/manuals/gs2m/gs2m.pdf#page=134 Page 134] (5-30 in the PDF) shows the RS-232/RS-485 wiring
NOTE: the manual lists the RS-485 wiring SG+ and SG- swapped! SG+ is really B- and SG- is really A+, this is the correct RJ12 (6P4C) pinout:
{| class="wikitable"
! RJ12 Pin
! Function
|-
| 2
| GND
|-
| 3
| A+ (manual says SG-!)
|-
| 4
| B- (manual says SG+!)
|-
| 5
| +5V
|}


== Dimensions ==
== Dimensions ==