Fuling DZB312 Series VFDs: Difference between revisions

added Modbus register table
added more PDF links
 
(4 intermediate revisions by the same user not shown)
Line 4: Line 4:


== Model Numbers ==
== Model Numbers ==
In the DZB312 series manual:


* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF)
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF)
In the DZB300 series manual:
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=7 Page 7] (marked 7 in the PDF) shows the model number scheme
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8] (marked 9 in the PDF) shows a table of model numbers and recommended component sizing
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=47 Page 47] (marked 88 in the PDF) shows the specifications based off the model number ranges


== Wiring Diagram ==
== Wiring Diagram ==
In the DZB312 series manual:


* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF)
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=5 Page 5] (marked 7 in the PDF)
In the DZB300 series manual:
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=8 Page 8-9] (marked 10-11 in the PDF) shows an overview of the wiring
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=9 Page 9] (marked 12 in the PDF) shows a the power terminal pinout
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=10 Page 10] (marked 13 in the PDF) shows a the control terminal pinout


== Dimensions ==
== Dimensions ==
In the DZB312 series manual:


* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF)
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=18 Page 18] (marked 33 in the PDF)


== Modbus control ==
In the DZB300 series manual:
 
* https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=55 Page 55] (marked 104 in the PDF)
 
== Parameters ==
 
In the DZB312 series manual:
 
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=10 Page 10] (marked 18 in the PDF) shows the list of parameters
 
In the DZB300 series manual:
 
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=15 Page 15] (marked 23 in the PDF) shows the list of parameters
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=21 Page 21] (marked 36 in the PDF) shows the detailed description of the parameters


=== VFD parameters ===
== Fault Codes ==


In the DZB312 series manual:
In the DZB312 series manual:


* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=10 Page 10] (17 in the PDF) gives the parameter list
* [https://www.cncwiki.org/images/f/f9/Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf#page=16 Page 16] (marked 29 in the PDF) shows a list of fault codes


Here are the ones relevant for Modbus control:
In the DZB300 series manual:
 
* [https://www.cncwiki.org/images/a/a4/Fuling_DZB300_Series_Inverter_User_Manual.pdf#page=43 Page 43] (marked 79 in the PDF) has a flowchart for diagnosing issues
 
== Modbus control ==
 
=== VFD parameters ===
 
Parameters relevant for Modbus control:


{| class="wikitable"
{| class="wikitable"
Line 139: Line 178:
| 0x2000
| 0x2000
| 8192
| 8192
| R/W ?
| R/W
| ???
| -10000 - +100000 (frequency/PID percentage * 100)
| frequency/PID setpoint percentage (?)
| frequency/PID setpoint percentage
|-
|-
| 0x3000
| 0x3000
| 12288
| 12288
| R?
| R
|  
| (decimal Hz * 10)
| frequency setpoint?
| frequency setpoint
|-
|-
| 0x3001
| 0x3001
Line 158: Line 197:
| 12290
| 12290
| R
| R
|  
| ???
| output current
| output current
|-
|-
Line 170: Line 209:
| 12292
| 12292
| R
| R
| ???
| (rpm using parameter F1.03)
| output speed?
| output speed
|-
|-
| 0x3005
| 0x3005
Line 177: Line 216:
| R
| R
| ???
| ???
| output power?
| output power
|-
|-
| 0x3006
| 0x3006
| 12294
| 12294
| R
| R
|  
| ???
| output torque?
| output torque
|-
|-
| 0x3007
| 0x3007
Line 193: Line 232:
| 0x5000
| 0x5000
| 20480
| 20480
| R?
| R
| ???
| ???
| inverter fault address?
| inverter fault address
|-
|-
| 0x5001
| 0x5001
Line 203: Line 242:
| Modbus communication fault
| Modbus communication fault
|}
|}
=== mbpoll ===
<pre># fault reset (need to test)
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 7
# stop
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 5
# set forward run
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 1
# set reverse run
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000 -t 4:int16 -- 2
# set the output frequency/rpm/PID percentage (percentage * 100)
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x2000 -t 4:int16 -- 10000
# monitor command (whatever was previously written, can be invalid)
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1000
# monitor inverter status
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x1001
# monitor commanded frequency
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3000
# monitor output frequency
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3001
# monitor output current
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3002
# monitor output voltage
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3003
# monitor output rpm
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x3004
# monitor inverter fault
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x5000
# monitor Modbus communication fault
./mbpoll /dev/ttyUSB0 -b 9600 -s 1 -P none -a 1 -0 -r 0x5001</pre>


== PDFs ==
== PDFs ==


[[Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf]] (not available online?)
[[Media:Fuling_DZB312_Series_Carving_Machine_Inverter_User_Manual.pdf]] (not available online?)
[[Media:Fuling_DZB300_Series_Inverter_User_Manual.pdf]]


== Online Resources ==
== Online Resources ==