AutomationDirect DURApulse GS20 Series VFDs: Difference between revisions
added downloads link |
added parameter, error code, and Modbus information |
||
| (One intermediate revision by the same user not shown) | |||
| Line 44: | Line 44: | ||
| 245,048,446 bytes | | 245,048,446 bytes | ||
| f274adb0afc390d777bdcfc624b7e17a | | f274adb0afc390d777bdcfc624b7e17a | ||
| | | 02c591e95576d2e8180062f4f8b04d36ec478046 | ||
|} | |} | ||
| Line 60: | Line 60: | ||
| c43013f34c64291d8c4b2ebfa4cbab2a1f68ff27 | | c43013f34c64291d8c4b2ebfa4cbab2a1f68ff27 | ||
|} | |} | ||
== Parameters == | |||
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=89 Page 89] (4-3 in the PDF) has the parameter table | |||
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=136 Page 139] (4-50 in the PDF) gives detailed descriptions of the parameters | |||
== Alarm Codes == | |||
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=384 Page 384] (6-8 in the PDF) list the warning codes | |||
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=401 Page 401] (6-25 in the PDF) list the fault codes | |||
== Modbus control == | |||
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=359 Page 359] (5-1 in the PDF) is the chapter on "Serial Communications" | |||
=== VFD parameters === | |||
{| class="wikitable" | |||
! Modbus Address | |||
! Parameter No. | |||
! Default Value | |||
! Required Value | |||
! Description | |||
|- | |||
| 0x0014 | |||
| P00.20 | |||
| 0: digital keypad | |||
| 1: RS-485 communication input | |||
| Master frequency command source | |||
|- | |||
| 0x0015 | |||
| P00.21 | |||
| 0: digital keypad | |||
| 2: RS-485 communication input | |||
| Operation command source | |||
|- | |||
| 0x0900 | |||
| P09.00 | |||
| 1 | |||
| 1 | |||
| Slave Address | |||
|- | |||
| 0x0901 | |||
| P09.01 | |||
| 9.6 | |||
| 9.6 | |||
| Baudrate | |||
|- | |||
| 0x0902 | |||
| P09.02 | |||
| 3: no warning, no fault, and continue operation | |||
| 2: fault and coast to stop | |||
| Communication Fault Handling | |||
|- | |||
| 0x0903 | |||
| P09.03 | |||
| 0.0 | |||
| 2.0 | |||
| Timeout Detection | |||
|- | |||
| 0x0904 | |||
| P09.04 | |||
| 15: 8, O, 1 (RTU) | |||
| 15: 8, O, 1 (RTU) | |||
| Communication Protocol | |||
|- | |||
| 0x0909 | |||
| P09.09 | |||
| 2.0 | |||
| 2.0 | |||
| Communication Response Delay | |||
|} | |||
From [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=360 Page 360] (5-2 in the PDF) | |||
=== Modbus registers === | |||
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=364 Page 364] (5-6 in the PDF) lists the status registers | |||
== Bill of Materials == | == Bill of Materials == | ||