AutomationDirect DURApulse GS20 Series VFDs: Difference between revisions

updated software links
added parameter, error code, and Modbus information
 
(2 intermediate revisions by the same user not shown)
Line 44: Line 44:
| 245,048,446 bytes
| 245,048,446 bytes
| f274adb0afc390d777bdcfc624b7e17a
| f274adb0afc390d777bdcfc624b7e17a
| SHA1
| 02c591e95576d2e8180062f4f8b04d36ec478046
|}
|}


Line 60: Line 60:
| c43013f34c64291d8c4b2ebfa4cbab2a1f68ff27
| c43013f34c64291d8c4b2ebfa4cbab2a1f68ff27
|}
|}
== Parameters ==
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=89 Page 89] (4-3 in the PDF) has the parameter table
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=136 Page 139] (4-50 in the PDF) gives detailed descriptions of the parameters
== Alarm Codes ==
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=384 Page 384] (6-8 in the PDF) list the warning codes
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=401 Page 401] (6-25 in the PDF) list the fault codes
== Modbus control ==
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=359 Page 359] (5-1 in the PDF) is the chapter on "Serial Communications"
=== VFD parameters ===
{| class="wikitable"
! Modbus Address
! Parameter No.
! Default Value
! Required Value
! Description
|-
| 0x0014
| P00.20
| 0: digital keypad
| 1: RS-485 communication input
| Master frequency command source
|-
| 0x0015
| P00.21
| 0: digital keypad
| 2: RS-485 communication input
| Operation command source
|-
| 0x0900
| P09.00
| 1
| 1
| Slave Address
|-
| 0x0901
| P09.01
| 9.6
| 9.6
| Baudrate
|-
| 0x0902
| P09.02
| 3: no warning, no fault, and continue operation
| 2: fault and coast to stop
| Communication Fault Handling
|-
| 0x0903
| P09.03
| 0.0
| 2.0
| Timeout Detection
|-
| 0x0904
| P09.04
| 15: 8, O, 1 (RTU)
| 15: 8, O, 1 (RTU)
| Communication Protocol
|-
| 0x0909
| P09.09
| 2.0
| 2.0
| Communication Response Delay
|}
From [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=360 Page 360] (5-2 in the PDF)
=== Modbus registers ===
* [https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf#page=364 Page 364] (5-6 in the PDF) lists the status registers


== Bill of Materials ==
== Bill of Materials ==
Line 76: Line 154:


[https://www.automationdirect.com/drives/ac-drives/gs20 AC Drives GS20 and GS20X | AutomationDirect]
[https://www.automationdirect.com/drives/ac-drives/gs20 AC Drives GS20 and GS20X | AutomationDirect]
[https://www.automationdirect.com/adc/shopping/catalog/drives_-a-_soft_starters/ac_variable_frequency_drives_(vfd)/general_purpose_vfds/gs23-45p0#docsanchor AutomationDirect DURApulse GS23-45P0 Downloads]


[https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf AutomationDirect DURApulse GS20 & GS20X Drive User Manual (GS20_UMW, 1st Edition, Rev D)]
[https://cdn.automationdirect.com/static/manuals/gs20m/gs20m.pdf AutomationDirect DURApulse GS20 & GS20X Drive User Manual (GS20_UMW, 1st Edition, Rev D)]