Folinn H1 Series VFDs: Difference between revisions

added MODBUS register address scheme notes
No edit summary
Line 35: Line 35:


* [https://www.omc-stepperonline.com/download/H1_Series_Inverter_Full_User_Manual.pdf#page=65 Page 65] (126 in the PDF) show a table of the dimensions
* [https://www.omc-stepperonline.com/download/H1_Series_Inverter_Full_User_Manual.pdf#page=65 Page 65] (126 in the PDF) show a table of the dimensions
== Parameters ==
{| class="wikitable"
! Parameter No.
! Default Value
! Range
! Description
|-
| P02.18
| 50.000 Hz
| 0.000 - 99999.000 Hz
| Maximum setting value
|-
| P02.19
| 0.000 Hz
| 0.000 - 99999.000 Hz
| Minimum setting value
|-
| P02.50
|
| 0.050 - 3600.000 s
| Acceleration time 0
|-
| P02.70
|
| 0.050 - 3600.000 s
| Deceleration time 0
|-
| P05.08
| 55.000 Hz
| -1020.000 - 1020.000 Hz
| Motor upper frequency limit
|-
| P06.00
|
| 0: off<br/>1: complete<br/>2: simple
| Motor parameter self-learning
|-
| P06.10
| 0: asynchronous
| 0: asynchronous<br/>1: surface mount permanent magnet synchronous<br/>2: salient pole permanent magnet synchronous<br/>4: single-phase motor
| Motor type
|-
| P06.05
|
| 2-16 kHz
| Carrier frequency
|-
| P06.11
|
| 0.000 - 100000.000 kW
| Motor rated power
|-
| P06.12
|
| 0 - 1000 V
| Motor rated voltage
|-
| P06.13
|
| 1 - 3000 Hz
| Motor rated frequency
|-
| P06.14
|
| 0.00 - 1000.00 A
| Motor rated current
|-
| P06.15
|
| 10 - 65535 RPM
| Motor rated speed
|-
| P06.16
|
| 0.00 - 1.00 (ratio)
| Motor power factor
|-
| P06.17
|
| 2 - 100 poles (not pairs)
| Motor pole count
|-
| P06.18
|
| 0.1 - 10000.0 Nm
| Motor rated torque
|-
| P06.19
|
| 0.00 - 1000.00 A
| Motor no-load current
|-
| P06.20
|
| 1.000 - 10000.000 mV/RPM
| PM motor back EMF/rev
|-
| P06.40
|
| 0.000 - 99.990 ohms
| Stator impedance
|-
| P06.41
|
| 0.000 - 99.990 ohms
| Rotor impedance
|-
| P06.42
|
| 0.000 - 999.990 mH
| Stator leakage reactance
|-
| P06.44
|
| 0.00 - 999.90 mH
| Motor main reactance
|}


== Modbus control ==
== Modbus control ==