WEIDE B2 Series Servo Drives: Difference between revisions

added CN2 DE9 pinout
added parameters, alarm codes, and Modbus control sections
Line 63: Line 63:


* [http://sevo.cn/upload/file_material/2021-04-14/1618365224b55d05ac7df1730c.pdf#page=10 Page 10] (7 in the PDF) shows the servo drive dimensions
* [http://sevo.cn/upload/file_material/2021-04-14/1618365224b55d05ac7df1730c.pdf#page=10 Page 10] (7 in the PDF) shows the servo drive dimensions
== Parameters ==
* [http://sevo.cn/upload/file_material/2021-04-14/1618365224b55d05ac7df1730c.pdf#page=50 Page 50] (47 in the PDF) has a parameter list
* [http://sevo.cn/upload/file_material/2021-04-14/1618365224b55d05ac7df1730c.pdf#page=62 Page 62] (59 in the PDF) has the parameter descriptions
== Alarm Codes ==
* [http://sevo.cn/upload/file_material/2021-04-14/1618365224b55d05ac7df1730c.pdf#page=107 Page 107] (104 in the PDF) has a list of the alarm codes
== Modbus Control ==
Parameters related to Modbus/RS-485:
{| class="wikitable"
! Parameter No.
! Values
! Default
! Description
|-
| 106
|
{| class="wikitable"
! Value
! Baudrate
|-
| 1
| 4,800 baud
|-
| 2
| 9,600 baud
|-
| 3
| 19,200 baud
|-
| 4
| 38,400 baud
|-
| 5
| 57,600 baud
|-
| 6
| 115,200 baud
|-
| other
| 9,600 baud
|}
| 2
| Modbus baud rate
|-
| 107
|
{| class="wikitable"
! Value
! Protocol
! Data Bits
! Stop Bits
! Parity
|-
| 0
| ASCII
| 8
| 2
| none
|-
| 1
| ASCII
| 8
| 1
| none
|-
| 2
| ASCII
| 8
| 1
| even
|-
| 3
| ASCII
| 8
| 1
| odd
|-
| 4
| ASCII
| 8
| 2
| even
|-
| 5
| ASCII
| 8
| 2
| odd
|-
| 6
| RTU
| 8
| 1
| none
|-
| 7
| RTU
| 8
| 1
| even
|-
| 8
| RTU
| 8
| 1
| odd
|-
| 9
| RTU
| 8
| 2
| odd
|}
| 6: RTU, 8 data bits, 1 stop bit, no parity
| Modbus Protocol
|-
| 108
| 0-247
| 1
| Modbus Slave Address
|}


== Replacement Parts ==