SUNFAR E380 Series VFDs: Difference between revisions
initial page creation |
added Chinese company name and website links |
||
| (4 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
== Overview == | == Overview == | ||
Variable Frequency Drives (VFDs) made by | Variable Frequency Drives (VFDs) made by "深圳市四方电气技术有限公司" (Shenzhen Sunfar Electric Technology Co., Ltd.), now known as "深圳市四方电气技术有限公司" (Shenzhen Simphoenix Electric Technology Co., Ltd). | ||
== Model Numbers == | == Model Numbers == | ||
| Line 48: | Line 48: | ||
* [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=76 Page 76] (69 in the PDF) descrives the proprietary SUNFAR protocol | * [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=76 Page 76] (69 in the PDF) descrives the proprietary SUNFAR protocol | ||
* [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=93 Page 93] (86 in the PDF) describes the Modbus protocol | * [https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf#page=93 Page 93] (86 in the PDF) describes the Modbus protocol | ||
=== VFD Parameters === | |||
{| class="wikitable" | |||
! Parameter No. | |||
! Default Value | |||
! Required Value | |||
! Description | |||
|- | |||
| F0.1 | |||
| 0: keypad (not POT) | |||
| 2: RS-485 | |||
| Frequency Source | |||
|- | |||
| F0.4 | |||
| 1: external terminals | |||
| 2: RS-485 | |||
| Run Source | |||
|- | |||
| F9.0 | |||
| 0014: proprietary protocol, 9600 baud, even parity | |||
| 0114: MODBUS RTU protocol, 9600 baud, even parity | |||
| RS-485 Mode | |||
|- | |||
| F9.1 | |||
| 0? | |||
| 1 | |||
| Slave Address | |||
|- | |||
| F9.2 | |||
| 5ms | |||
| 5ms | |||
| Response Delay Time | |||
|- | |||
| F9.3 | |||
| 0010: keep running | |||
| 0000: stop running | |||
| Timeout & Master/Slave Behavior | |||
|- | |||
| F9.4 | |||
| 2.0 s | |||
| 10.0 s | |||
| Communication Timeout | |||
|} | |||
=== Modbus Registers === | |||
Readable registers (function code 3): | |||
{| class="wikitable" | |||
! Parameter No. | |||
! Address | |||
! Value | |||
! Description | |||
|- | |||
| | |||
| 0x2000 | |||
| 0x0000: Slave DC voltage is not prepared<br/>0x0001: Slave forward running<br/>0x0002: Slave reverse running<br/>0x0003: Slave stop<br/>0x0004: Slave forward jog running<br/>0x0005: Slave reverse jog running<br/>0x0011: Forward accelerating<br/>0x0012: Reverse accelerating<br/>0x0013: Instantaneous stop and restart<br/>0x0014: Forward decelerating<br/>0x0015: Reverse decelerating<br/>0x0016: Slave is under DC braking status<br/>0x0020: Slave is on fault status | |||
| Inverter Status | |||
|- | |||
| | |||
| 0x2001 | |||
| ? | |||
| Fault Information | |||
|- | |||
| d-00 - d-37 | |||
| 0xD000 - 0xD025 | |||
| | |||
| Monitoring | |||
|- | |||
| F0.0 - F0.18? | |||
| 0xF000 - 0xF0D1 | |||
| | |||
| F0.xx | |||
|- | |||
| F1.0 - F1.18? | |||
| 0xF100 - 0xF1BE | |||
| | |||
| F1.xx | |||
|- | |||
| F2.0 - F2.18? | |||
| 0xF200 - 0xF2AB | |||
| | |||
| F2.xx | |||
|- | |||
| F3.0 - F3.16? | |||
| 0xF300 - 0xF398 | |||
| | |||
| F3.xx | |||
|- | |||
| F4.0 - F4.28? | |||
| 0xF400 - 0xF487 | |||
| | |||
| F4.xx | |||
|- | |||
| F5.0 - F5.26? | |||
| 0xF500 - 0xF56A | |||
| | |||
| F5.xx | |||
|- | |||
| F6.0 - F6.19? | |||
| 0xF600 - 0xF64F | |||
| | |||
| F6.xx | |||
|- | |||
| F7.0 - F7.8? | |||
| 0xF700 - 0xF739 | |||
| | |||
| F7.xx | |||
|- | |||
| F8.0 - F8.24? | |||
| 0xF800 - 0xF832 | |||
| | |||
| F8.xx | |||
|- | |||
| F9.0 - F9.11? | |||
| 0xF900 - 0xF919 | |||
| | |||
| F9.xx | |||
|- | |||
| rowspan="2" | FC.0 - FC.13? | |||
| 0xFA00 - 0xFA0D | |||
| | |||
| FC.xx? | |||
|- | |||
| 0xFC00 - 0xFC0D | |||
| | |||
| FC.xx? | |||
|} | |||
Writable registers (function 6): | |||
{| class="wikitable" | |||
! Address | |||
! Value | |||
! Description | |||
|- | |||
| 0x1000 | |||
| ? | |||
| "Given by PID"? | |||
|- | |||
| 0x1001 | |||
| 0x00: Invalid<br/>0x01: Forward run to start<br/>0x02: Reversion run to start<br/>0x03: Stop<br/>0x04: Slave forward jog<br/>0x05: Slave reversion jog<br/>0x06: Jog run to stop<br/>0x20: Slave fault reset<br/> | |||
| Operating Command | |||
|- | |||
| 0x1002 | |||
| 0.00 - 600.00 Hz | |||
| Frequency Setting | |||
|} | |||
== Online Resources == | == Online Resources == | ||
[https://www.simphoenix.com.cn/product/Detail.aspx?id=100000023014378 VS500雕刻机专用变频器] (VFD product page from the same company) | |||
[https://www.simphoenix.com.cn/support/index.aspx?nc=101033004 深圳市四方电气技术有限公司] (product support page listing the E380 model) | |||
[https://www.simphoenix.com.cn/UploadFiles/Files/2023/11/20231107052736781.pdf SUNFAR E380 Series Universal Inverter User Manual (V2.7, May 2013, Chinese)] | |||
[https://www.simphoenix.com.cn/UploadFiles/Files/2023/11/20231107054055421.pdf Simphoenix E380 Series Universal Inverter Brochure (Chinese)] | |||
[https://salecnc.com/manuals/Inverter/E380%20Series%20Manual.pdf SUNFAR E380 Series of General Purpose Inverter Operation Manual] (salecnc.com, 88 pages) | [https://salecnc.com/manuals/Inverter/E380%20Series%20Manual.pdf SUNFAR E380 Series of General Purpose Inverter Operation Manual] (salecnc.com, 88 pages) | ||
| Line 55: | Line 212: | ||
[https://www.simphoenix.com/uploads/dd9abed8.pdf SUNFAR E380 Series of General Purpose Inverter Operation Manual] (simphoenix.com, 112 pages) | [https://www.simphoenix.com/uploads/dd9abed8.pdf SUNFAR E380 Series of General Purpose Inverter Operation Manual] (simphoenix.com, 112 pages) | ||
[https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf SUNFAR E550 Series Universal Low-Power Inverter User Manual] (purelogic.ru, 100 pages) | <del>[https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf SUNFAR E550 Series Universal Low-Power Inverter User Manual] (purelogic.ru, 100 pages)</del> | ||
[https://web.archive.org/web/20210829121720/https://purelogic.ru/docs/elektronika/chastotnye_preobrazovateli_sunfar_seriya_e550_user_manual_ru.pdf SUNFAR E550 Series Universal Low-Power Inverter User Manual] (purelogic.ru, 100 pages) (Wayback Machine) | |||
[https://cdn.awsli.com.br/298/298780/arquivos/Serie%20e550.pdf SUNFAR E550 Series Universal Low-Power Inverter User Manual] | |||
[https://cdn.awsli.com.br/298/298780/arquivos/Serie%20e300.pdf SUNFAR E300 Series Mini-type Integrated Universal Inverter Manual] | [https://cdn.awsli.com.br/298/298780/arquivos/Serie%20e300.pdf SUNFAR E300 Series Mini-type Integrated Universal Inverter Manual] | ||